北京肅為電器設備有限公司
BEIJING SUWEI CO .,LTD
SW60 Technical Information
Application |
Interrupted Uninterrupted |
|
Thermal Current Rating |
80A |
80A |
Intermittent Current Rating: |
||
30% Duty |
145A |
145A |
40% Duty |
125A |
125A |
50% Duty |
115A |
115A |
60% Duty |
105A |
105A |
70% Duty |
95A |
95A |
Rated Fault Current Breaking Capacity (Icn) 5ms Time Constant:(In accordance with UL583*) |
||
Blowouts |
400A at 96V D.C. |
|
No Blowouts |
400A at 48V D.C. |
|
Rated Fault Current Breaking Capacity (Icn) Resistive Load:(In accordance with UL508*) |
||
Blowouts |
120A at 96V D.C. |
|
No Blowouts |
120A at 48V D.C. |
|
Maximum Recommended Contact Voltages |
||
Blowouts |
96V |
120V |
No Blowouts |
48V |
60V |
Typical Voltage Drop per pole across New Contacts at 80A |
40mV |
|
|
||
Mechanical Durability |
> 3,000,000 Cycles |
|
Coil Voltage Available (Us) (Rectifier board required for A.C.) |
6 - 130V |